ROGERELE REP1500 provides 1500W rated pure sine wave AC output with 3000W listed peak power. Select a 12V, 24V or 48V DC model, AC output voltage and market-specific outlet. Review six model codes, protection settings and packing data for distribution and equipment integration.

Online Inquiry
ROGERELE · REP1500
ROGERELE REP1500 1500W pure sine wave inverter product view
REP1500 · Product view
REP1500 · FOR DISTRIBUTORS & EQUIPMENT BRANDS

1500W Pure Sine Wave Inverter

Specify a 1500W pure sine wave inverter for your distribution range or battery-powered equipment. Select the DC input, AC output and outlet required for your destination market.
1500W rated · 3000W peak
Pure sine wave output. Peak duration is not specified.
DC input versions
12V / 24V / 48V
AC output options
100 / 110 / 120V or 220 / 230 / 240V
Dimensions & weight
310 × 180 × 80 mm · 2.9 kg net
Tell us your application, destination market and quantity. We will help confirm the exact configuration.
01 / HARDWARE & INSTALLATION

Check the details before integration.

REP1500 provides pure sine wave AC, with THD below 3% under a linear load, listed maximum efficiencies of 90% / 92% / 95% for 12V / 24V / 48V versions and QC3.0 USB on 12V / 24V versions (USB is not listed for the 48V version). Match the rated output to your actual equipment load.
REP1500 positive and negative DC input terminals and cooling fan
REP1500 · DC terminals & cooling fan
Installation checklist
Battery input
Choose the 12V, 24V or 48V version that matches your battery. Check the model-specific input range.
Cable & airflow
Allow access to the DC terminals and leave ventilation space around the cooling fan.
Installation documents
Request the current mechanical drawing and wiring instructions before confirming mounting, cables and protection.

02 / DESTINATION-MARKET OPTIONS

Choose the outlet for your market.

Specify socket type, AC voltage and frequency separately. The photos show configuration examples; confirm the exact version in your order.

Outlet configuration options
Multi-format outlet configuration example for REP1500 sourcing
Multi-format outlet
UK-style outlet configuration example for REP1500 sourcing
UK-style outlet
South African-style outlet configuration example for REP1500 sourcing
South African-style outlet
US-style outlet configuration example for REP1500 sourcing
US-style outlet
REP1500 Schuko-style outlet configuration
Schuko-style outlet
REP1500 Australian-style outlet configuration
Australian-style outlet

Six outlet examples for REP1500. Click a photo to enlarge. Confirm outlet availability, AC voltage, frequency and required market documentation for your order.

03 / TECHNICAL SPECIFICATIONS

The figures behind your selection.

Performance and operating conditions

Parameter
Specification
Rated / peak output
1500W / 3000W; peak duration not specified
Waveform / distortion
Pure sine wave / THD <3% with linear load
Output frequency
50Hz ±0.5Hz or 60Hz ±0.5Hz
Maximum efficiency
12V: 90%; 24V: 92%; 48V: 95%. Maximum values vary with load and conditions
USB / cooling
12V / 24V: QC3.0; 48V: not listed · Intelligent air cooling
Operating / storage temperature
−10°C to +50°C / −30°C to +70°C
Listed warranty
2 years; confirm coverage and service terms

04 / SIX MODEL CODES

Order the exact electrical variant.

Choose one DC input and one AC output voltage. The voltages in each AC family are ordering options, not user-switchable settings on every unit.

REP1500-121
DC input
12V
AC output ±5%
100 / 110 / 120V
No-load current
<0.8A
REP1500-241
DC input
24V
AC output ±5%
100 / 110 / 120V
No-load current
<0.4A
REP1500-481
DC input
48V
AC output ±5%
100 / 110 / 120V
No-load current
<0.2A
REP1500-122
DC input
12V
AC output ±5%
220 / 230 / 240V
No-load current
<0.8A
REP1500-242
DC input
24V
AC output ±5%
220 / 230 / 240V
No-load current
<0.4A
REP1500-482
DC input
48V
AC output ±5%
220 / 230 / 240V
No-load current
<0.2A

Battery-side operating ranges

Parameter
Specification
12V input variant
10–15.5V
24V input variant
20–31V
48V input variant
40–61V

The catalog lists low-voltage, over-voltage, overload and over-temperature protection, short-circuit indication and fuse operation for reverse polarity. Confirm the settings and protection behavior for the ordered model.

Custom DC inputs: the catalog lists 36V, 60V, 72V, 84V and 96V as customization options. Confirm feasibility, operating range, quantity and lead time for your project before ordering.

Voltage protection reference

Parameter
Specification
Low-voltage alarm (12V / 24V / 48V)
10.5 ±0.5V / 21 ±0.5V / 42 ±1V
Low-voltage cutoff (12V / 24V / 48V)
10 ±0.5V / 20 ±0.5V / 40 ±0.5V
Over-voltage cutoff (12V / 24V / 48V)
15.5 ±0.5V / 31 ±0.5V / 61 ±1V
Low-voltage recovery (12V / 24V / 48V)
12.3 ±0.5V / 24 ±0.5V / 48 ±1V
Over-voltage recovery (12V / 24V / 48V)
14.8 ±0.5V / 29.5 ±0.5V / 59 ±1V

Dimensions and packing

Parameter
Specification
Product dimensions
310 × 180 × 80 mm
Packing dimensions
345 × 230 × 130 mm
Net / gross weight
2.9 / 3.4 kg
Units per carton
6 pcs
Carton dimensions
490 × 360 × 440 mm
Carton gross weight
20.4 kg

Confirm the final drawing and packing data before integration or freight booking.

05 / BUSINESS SOURCING

Build a complete purchasing specification.

01

Distributors

Prepare your market specification.
• Destination country & outlet
• Initial quantity & repeat demand
• Product documents & packing data
02

Equipment brands

Define the integration requirements.
• Load profile & battery voltage
• Installation space & environment
• Branding & customization review
03

Purchasing teams

Confirm the order conditions.
• Samples, MOQ & production lead time
• Required market documentation
• Warranty & service arrangements

Frequently asked purchasing questions

Can one REP1500 accept 12V, 24V and 48V batteries?
No. These are separate model variants with different input ranges. Choose the version that matches your battery voltage.
Is REP1500 a battery charger or solar controller?
REP1500 is a DC-to-AC inverter. The published specification does not list battery charging, a solar charge controller or automatic UPS transfer. Discuss those functions separately if your project needs them.
Does the 3000W peak rating guarantee motor startup?
No. The published peak figure has no duration or startup test condition. Provide the equipment and starting characteristics for a suitability review.
What should I include in a quotation request?
Include company name, application, REP1500 model code, DC input, AC voltage and frequency, outlet, destination country, quantity and required documentation. Add branding or packaging requirements where applicable.
Can I request samples or custom branding?
Send the proposed configuration and quantity. Sample availability, branding feasibility, MOQ and production lead time are confirmed per quotation.

REP1500 product videos

Review the published motherboard and inverter test videos. Confirm the ordered configuration and test conditions with our team.

1500W inverter motherboard

ROGERELE 1500W inverter test

ROGERELE REP1500 1500W pure sine wave inverter with gold aluminum housing

ROGERELE pure sine wave inverter front panel with multi-format AC outlet and LCD display

REP1500 inverter with South African-style AC outlet

REP1500 inverter with two US-style AC outlets

REP1500 inverter with UK-style AC outlet

REP1500 inverter with Australian-style AC outlet

REP1500 inverter with Schuko-style AC outlet